CGMWF - FASTBOND 42-NF PLUS NV INSULATION ADHESIVE

  • MSDS: CGMWF
  • Manufacturer: 3M INDUSTRIAL SPECIALTIES DIV
  • Product Name: FASTBOND 42-NF PLUS NV INSULATION ADHESIVE
  • National Stock Number: 1680-00-808-0748
Product Identification

Product ID:FASTBOND 42-NF PLUS NV INSULATION ADHESIVE
MSDS Date:03/12/1997
FSC:1680
NIIN:00-808-0748
Kit Part:Y
MSDS Number: CGMWF

Responsible Party
3M, INDUSTRIAL SPECIALTIES DIVISION
3M CENTER
SAINT PAUL, MN 55144-1000
US

Emergency Phone: 612-733-1110

Info Phone: 612-733-1110

Cage: 52152

Contractor
MINNESOTA MINING & MFG CO INDUSTRIAL TAPE & SPECIALTIES
ST PAUL, MN 55144-1000 US

Telephone: 1-800-364-3577

Cage: 52152

Ingredients

ASPHALT (PETROLEUM)

CAS: 8052-42-4

RTECS: CI9900000

Fraction By Weight: 35-45%

ACGIH TLV: 5 MG/M3; (FUME);9596


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 30-40%

OSHA PEL NOT RELEVANT

ACGIH TLV: NOT RELEVANT


BUTADIENE-STYRENE POLYMER (RUBBER)

CAS: 9003-55-8

RTECS: WL6478000

Fraction By Weight: 10-20%


TALL-OIL ROSIN

CAS: 8052-10-6

Fraction By Weight: 5-20%


CASEINS

CAS: 9000-71-9

Fraction By Weight: 0.5-1.5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT MAY CAUSE SKIN & EYE
IRRITATION. HEALTH EFFECTS FROM INHALATION ARE NOT EXPECTED UNLESS
PRODUCT IS HEATED. INGESTION MAY CAUSE ABDOMINAL PAIN. NOTE:
EXPOSURE TO THIS MATERIAL IN NORMAL STORAGE & HANDLING HAS NOT
BEEN REPORTED TO CAUSE SIGNIFIGANT ADVERSE HEALTH EFFECTS.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN BY IARC, NTP OR OSHA.
Effects of Overexposure:EYES-REDNESSS, SWELLING, PAIN, TEARING.
SKIN-REDNESS, SWELLING, ITCHING. INGESTED-ABDOMINAL PAIN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES-FLUSH WITH LOTS OF WATER FOR 15 MINUTES, HOLD LIDS OPEN.
GET IMMEDIATE MEDICAL ATTENTION. SKIN-FLUSH WITH LOTS OF WATER.
SEEK MEDICAL ATTENTION IF SYMPTOMS PERSIST. INHALED-NONE NORMALLY
NEEDED. INGESTED-DO NOT INDUCE VOMITING! IF CONSCIOUS, DRINK 2
GLASSES WATER. CALL A PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, FOAM, WATER.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND
FULL FACE-PIECE SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:OBSERVE PRECAUTIONS FROM OTHER SECTIONS.
CONTAIN SPILL. COVER WITH ABSORBENT MATERIAL. CLEAN UP RESIDUE.
PLACE IN A POLYETHYLENE-LINED METAL CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT TEMPERATURES ABOVE 32F (0C).
KEEP CONTAINER CLOSED WHEN NOT IN USE. KEEP OUT OF REACH OF
CHILDREN.
Other Precautions:FOR INDUSTRIAL OR PROFESSIONAL USE ONLY.

Exposure Controls

Respiratory Protection:AVOID BREATHING OF VAPORS, MIST OR SPRAY.
Ventilation:USE INA WELL-VENTILATED AREA.
Protective Gloves:BUTYL, POLYETHYLENE, SARANEX.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING & BEFORE EATING.
Supplemental Safety and Health
KEY1=N1. PART A OF TWO PART KIT, SEE PNI B THIS NSN FOR PART B.

Chemical Properties

HCC:N1
Boiling Pt:>100.C, 212.F
Vapor Pres:17.5
Spec Gravity:1.02
pH:9-10
Viscosity:6K-110K CP
Evaporation Rate & Reference:<1 (WATER=1)
Solubility in Water:MODERATE
Appearance and Odor:BLACK LIQUID; SLIGHT ASPHALT ODOR.
Percent Volatiles by Volume:35-40

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE,
TOXIC VAPORS, GASES OR PARTICULATES.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION WILL NOT
OCCUR.

Disposal

Waste Disposal Methods:CURE PRODUCT ACCORDING TO PRODUCT INSTRUCTIONS.
INCINERATE IN AN INDUSTRIAL OR COMMERCIAL FACILITY. DISPOSE OF
COMPLETELY CURED (OR POLYMERIZED) MATERIAL IN A SANITARY LANDFILL.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.